Customization: | Available |
---|---|
Phase: | Single |
Type: | DC/AC Inverters |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type: | DX2000W | DX3000W | DX5000W | DX60000W | DX8000W | DX10000W | ||||
DC12V | DC24V | DC48V | DC12V | DC24V | DC48V | DC48V | DC48V | DC96V | DC96V | |
1.AC Mode Specifications: | ||||||||||
Input wave form | pure sine wave | |||||||||
Input voltage | 220Vac | |||||||||
Low voltage cut off | 145Vac±4% | 165Vac±4% | ||||||||
Low voltage recover | 155Vac±4% | 175Vac±4% | ||||||||
High voltage cut off | 285Vac±4% | 265Vac±4% | ||||||||
High voltage recover | 275Vac±4% | 255Vac±4% | ||||||||
Frequency | 50Hz/60Hz(Atomatic detection) | |||||||||
Output wave form | pure sine wave | |||||||||
Overload protection | alarm | |||||||||
Short circuit protection | trip | |||||||||
Efficiency | >95% | |||||||||
Transfer current | 30A | 60A | ||||||||
Transfer time DC TO AC | 10ms | |||||||||
Transfer time AC TO DC | 10ms | |||||||||
2.Inverter Mode Specifications: | ||||||||||
Rated power | 2000W | 3000W | 5000W | 6000W | 8000W | 10000W | ||||
Power factor | 0~1.0 | |||||||||
Output voltage | 220Vac | |||||||||
Frequency | 50Hz ± 0.3Hz | |||||||||
Automatic tracking the main frequency | Yes(start from the first connection)50Hz @48-54Hz/ 60Hz @58-64Hz | |||||||||
Inputvoltage range | ±10% rms | (-25%/+20%) rms | ||||||||
Efficiency | >80% | |||||||||
Overload protection | (110%<load<125%) ±10%: 30S cut off output voltage | |||||||||
(SMPS load) | (125%<load<150%) ±10%:cut off output voltage at once | |||||||||
Peak Capacity | 4000VA | 6000VA | 10000VA | 12000VA | 16000VA | 20000VA | ||||
Short circuit protection | Yes | |||||||||
Input voltage | 12V/24V/48V/96V | |||||||||
Min DC voltage | 10V/20V/40V/80V | |||||||||
Undervoltage warning | 10.5Vdc ± 0.3Vdc (12V battery)/42Vdc±1.2Vdc(48V battery) | |||||||||
21.0Vdc ± 0.6Vdc (24V battery)/84Vdc±2.4Vdc(96V battery) | ||||||||||
DC input too low, | 10.0Vdc ± 0.3Vdc(12V battery)/40.0Vdc±1.2Vdc(48V battery) | |||||||||
Automatic cut off | 20.0vdc± 0.6Vdc (24V battery)/80.0Vdc±2.4Vdc(96V battery) | |||||||||
input voltage warning &cut off | 15Vdc ± 0.3Vdc (12V battery)/30Vdc ± 0.6Vdc(24V battery) | |||||||||
60Vdc±1.2Vdc(48V battery)/120Vdc±2.4Vdc(96V battery) | ||||||||||
Save power | load≤25W | |||||||||
3.Charger Mode Specifications: | ||||||||||
Chargering current | 50A | 25A | 15A | 50A | 25A | 15A | 15A | 15A | 15A | 15A |
Chargering current correction | ± 5Adc | |||||||||
Battery initial voltage | 0 -13.7 Vdc | |||||||||
Charger short circuit protection | trip | |||||||||
Overcharger protection | V ≥14.7Vdc / 30.4Vdc, every half second sounds | |||||||||
4.Charging Rules: | ||||||||||
Three Phases | constant current chargering →constant voltage phase →float | |||||||||
5.Monitor | ||||||||||
Computer Monitor | RS232 | |||||||||
6.Protection | ||||||||||
Low Voltage | LCD show low battery alarm | |||||||||
High Voltage | alarm | |||||||||
Inverter Mode overload | shut-down protection | |||||||||
Over Temperature | Heatsink temperature.≥90°C,shut-down protection | |||||||||
7.Physical | ||||||||||
Operate Temperature Range | 0°C to 40°C | |||||||||
Store Temperature | -15ºC ~ 60ºC | |||||||||
Operate Humidity | 5% to 95% | |||||||||
Noise | 60dB max | |||||||||
Cooling | fan in ventiltation conditions | |||||||||
Dimension(L*H*W) | 450*215*180MM | 450*215*180MM | 620*215*180MM | 580*290*675mm | ||||||
N.W (KG) | 20KG | 20KG | 20KG | 24KG | 24KG | 24KG | 44KG | 46KG | 80KG | 93.5KG |